Manufacturer data
Full specifications — Medallion POE-7-1354 and POE-10-1465
You do not need these tables to decide anything. They are here so you, or anyone you ask for a second opinion, can check the system against the manufacturer’s own sheet. The short version: one tank, 13 inches wide and 54 inches tall (POE-7, 6–8 gallons a minute) or 14 by 65 inches (POE-10, 8–10 gallons a minute), sized to your home’s peak flow, that works best on water inside the limits in the third table — which is exactly what the $185 test measures.
System
Medallion POE-7-1354 system specifications| Item | Manufacturer figure |
|---|
| Tank | 13″ W × 54″ H · gravel/stone underbed · 160 lbs |
|---|
| Media | Bayoxide® E33 iron-based arsenic adsorption media (AdEdge AD33), 2.75 cubic feet (4 in the POE-10-1465) |
|---|
| Flow | 6–8 GPM normal service · 8 GPM peak — sized for full-house supply |
|---|
| Backwash | Automatic, by gallons treated or every 28 days · 14 minutes plus a 2-minute rinse at 7.5 GPM, about 120 gallons (AdEdge’s manual; our arithmetic) |
|---|
| Connections | 1″ MPT PVC inlet/outlet · ¾″ drain |
|---|
| Control valve | LCD readout · flow totalizer for media tracking · built-in sample ports · built-in flow controls |
|---|
| Operating range | 33–100°F (brochure); the installation manual gives 40–110°F and 30–125 psi |
|---|
| Larger model | POE-10-1465: 14″ W × 65″ H · 4 cubic feet of E33 · 8–10 GPM, 10 peak · 10 GPM backwash · 230 lbs |
|---|
| Warranty | AdEdge publishes no homeowner warranty for the Medallion; any written warranty that ships with it is shown to you before you sign |
|---|
Performance (manufacturer)
Medallion POE-7-1354 performance| Item | Manufacturer figure |
|---|
| Arsenic range | 5–100 ppb influent recommended for best performance (AdEdge’s brochure lists 5–500 ppb, higher with AdEdge consulted) · treatment goal under 10 ppb total arsenic, the current EPA MCL |
|---|
| Types reduced | Arsenic V and arsenic III — greater capacity for arsenic V; AdEdge recommends pre-oxidation where arsenic III dominates |
|---|
| Removal efficiency | 90–99% typical |
|---|
| Media life | Depends on water quality and use — tracked by the flow totalizer and verified by treated-water tests (every 3 months, AdEdge); the exchange is priced flat when it is due |
|---|
| Spent media | Non-hazardous waste when applied as directed (passes EPA TCLP, AdEdge) — disposal under local rules |
|---|
Best-results water chemistry — why we test first
Outside these limits the media works less well or needs help ahead of it. Most of these are on the $185 panel; some, such as sulfide, need a separate test, and Neil checks your report against this list before anything is ordered.
Recommended incoming water chemistry for the Medallion POE| Item | Manufacturer figure |
|---|
| pH | 5.5–8.5 |
|---|
| Iron / manganese | under 0.5 mg/L / under 0.05 mg/L — higher levels are treated ahead of the Jaguar: a softener for clear-water iron up to about 2 mg/L (the supplier); an iron filter, the Panther, above that or for rusty iron |
|---|
| Silica / sulfides | under 30 mg/L / under 0.1 mg/L |
|---|
| Phosphate / sulfate / fluoride | under 0.5 mg/L / under 100 mg/L / under 1.0 mg/L |
|---|
| Hardness | under 300 mg/L, about 17.5 grains (AdEdge); above that, a softener goes before the AdEdge unit, and below it a softener is optional |
|---|
| Sediment | A 30-micron sediment pre-filter is included in every install (AdEdge’s installation list) |
|---|
How it compares (manufacturer data)
In plain terms: exchange resin and whole-house RO both need arsenic III converted first, both need salt or membrane cleaning, and RO sends a quarter to three-quarters of the water down the drain. The Medallion needs none of that, in AdEdge’s comparison below. Our arithmetic from AdEdge’s own manual puts its backwash water at about 2–4% of what a 2–4 person house uses, not the chart’s under 1%.
Arsenic treatment alternatives compared, from AdEdge’s data sheet| Feature | Anion exchange | Whole-House RO | The Jaguar Package (Medallion POE) |
|---|
| Arsenic treated | As V only | As V only | As V and As III |
|---|
| Pre-oxidation needed | Yes | Yes | Not usually — only for heavily arsenic III water |
|---|
| Chemical use | Salt | Membrane cleaning | None |
|---|
| Water wasted | 5% | 25–75% | under 1% |
|---|
| Hazardous waste | Yes | Concentrated reject | None |
|---|
| Off-taste potential | Yes | No | No |
|---|
| Maintenance | High | High | Low |
|---|
| Arsenic “dumping” | Possible | N/A | No |
|---|
After the install: treated-water tests (every 3 months, AdEdge; at least yearly, the University of Arizona) confirm the number, the totalizer tracks gallons toward the media change, and the media exchange is priced flat when it is due. Pair it with an under-sink RO system ($829) for a second barrier on drinking water.
Figures from AdEdge Water Technologies’ AdVantEdge Medallion Series POE data sheet and product brochure. Bayoxide® is a LANXESS trademark.