- Grain per gallon (gpg)
- The unit used to measure hardness: one grain per gallon is about 17 ppm (mg/L). The City of Prescott reports 4.3–7.6 grains; ADEQ’s study of Prescott-area wells averaged about 12.
- 32K, 48K, 64K
- A softener’s nominal size in thousands of grains. What it holds between regenerations is less; each sheet gives Charger’s rating.
- Regeneration
- A softener’s cleaning cycle: salt water renews the resin, then it rinses to the drain — about 40 to 140 gallons on the tanks on these sheets, by size, plus the slow salt-water rinse (our arithmetic from Charger’s settings).
- Backwash
- A filter rinsing itself by running water backward through the tank to a drain.
- Air draw
- How the Panther’s iron filter works: it keeps a pocket of air in the tank that turns dissolved iron and the rotten-egg gas into particles the media catches, and after each backwash it draws in fresh air, briefly emptying the tank of water to do it (Charger).
- Pressure drop and Cv
- The water pressure a valve or tank costs at a given flow. A valve’s flow coefficient (Cv) is the flow, in gallons a minute, at which it costs 1 psi; the drop at other flows is (flow ÷ Cv) squared.
- Limited warranty
- A written warranty that does not meet every one of the federal conditions for a “full” warranty — for example, one that covers only the original buyer, or limits how long implied warranties last. A written warranty on a product costing more than $10 must be called “full” or “limited” (FTC). Charger’s warranties on these packages say they are limited; each sheet’s Warranty row lists what is covered and what is excluded.
- Incidental and consequential damages
- Incidental damages are the costs of dealing with a failed part, such as inspecting it or shipping it back; consequential damages are the other losses it causes, such as water damage to a floor. Charger’s warranties on these packages cover neither.
- Implied warranty
- An unwritten promise that state law attaches to a sale — the FTC calls implied warranties “unspoken, unwritten promises, created by state law” — the most common being that a product does what it is sold to do. A limited written warranty may limit how long they last.
- Not certified
- No independent certifier (NSF, IAPMO or WQA) lists the product for that claim, so the claim is the maker’s own. EPA does not certify treatment devices.
- MCL and MCLG
- EPA’s Maximum Contaminant Level is the highest level allowed in drinking water on a public system; the MCL Goal is the level below which there is no known or expected risk to health. For lead the goal is zero (the water-testing page).
- Downstream
- Further along the pipe. A softener connected downstream of the outdoor spigots leaves those spigots on unsoftened water.
- Free chlorine residual
- Chlorine still active in the water at your tap, as in chlorinated city water. A private well normally has none.
- IAPMO Z601
- A standard for scale-reduction devices such as salt-free conditioners. IAPMO tests and lists products against it; none of the Snow Leopards claims it.
- Media
- The material in a tank that does the work: resin in a softener, carbon, KDF, SP3 or arsenic media.
- Resin
- The small plastic beads in a softener that trade hardness for sodium (or potassium).
- Crosslink
- How tightly a softener resin’s beads are bonded, in percent: 8% is the standard grade, and a higher percentage makes a tougher bead. The Tiger 48’s invoice lists 8% crosslink.
- Mineral tank and salt tank
- The tall tank holds the media. The salt (brine) tank is the one you fill with bags of salt.
- Mid-plate
- A plate inside a tank that keeps two media apart (Charger).
- KDF
- A copper-zinc media. Charger says it reduces chlorine, heavy metals and hydrogen sulfide.
- GAC and catalytic carbon
- Granular activated carbon takes out chlorine taste and smell. Regular carbon cannot remove chloramine; catalytic carbon can reduce it (Charger).
- Chloramine
- A disinfectant made from chlorine and ammonia that some cities use instead of chlorine.
- Clear-water iron
- Dissolved iron: the water runs clear from the tap, then turns orange or brown in the air.
- PFAS
- Man-made “forever chemicals” that break down very slowly. See the PFAS page.
- ppm, ppb, mg/L, µg/L
- Parts per million equal milligrams per liter (mg/L); parts per billion equal micrograms per liter (µg/L). Arsenic is usually given in ppb.
- ND (non-detect)
- Below the lowest level the lab’s method can reliably measure. It does not mean zero; your report gives the detection limit (the water-testing page).
- gpm and psi
- Gallons a minute, and pounds per square inch of water pressure.
- TDS
- Total dissolved solids: everything dissolved in the water, as one number. It says how much, not what.
- Turbidity (NTU)
- How cloudy the water is.
- Micron
- A millionth of a meter; a filter’s micron rating is the size of particle it catches.
- NSF/ANSI standards
- 42: taste and odor. 44: water softeners. 53: health claims such as arsenic, lead or PFAS. 55: UV. 58: under-sink reverse osmosis. 61 and 372: what a part adds to water — material safety, not performance. NSF, IAPMO and WQA test and list products; EPA does not certify treatment devices.
- Class A (UV)
- The NSF/ANSI 55 grade for UV units meant for water with harmful germs: a stronger dose with an alarm or automatic shutoff.
- Softener loop
- The pair of pipes a builder leaves for a softener, usually near the water heater or where the water comes in.
- Bypass valve
- A valve that sends water around the equipment, so the house keeps water while it is serviced.
- Air gap
- An open space between a drain line and the drain, so dirty water can never be pulled back into the system.
- Charger (and Charger Water)
- Charger Water Treatment Products of Morton Grove, Illinois, the supplier Neil buys most of this equipment from; its UV sheets say Charger Water. Some parts are made by others: the HydroSplash by Vertex, the SP3 media by Watch-Water.
- Arsenic III and arsenic V
- The two forms of arsenic in well water. Most treatment, RO included, works better on arsenic V; a standard lab panel reports the total, not the form. The University of Arizona says most Arizona aquifers contain arsenic V, so arsenic III is normally not a concern for Arizona well owners.
- Reverse osmosis (RO)
- Water pushed through a very fine membrane that holds back most dissolved solids; part of the water carries them to the drain.
- Recovery
- The share of the water going into an RO that comes out as purified water. At 50% recovery, a gallon goes to the drain for every gallon made.
- SP3, NAC and TAC
- Salt-free scale media. SP3 is Watch-Water’s product; its maker calls the process NAC. TAC media sold by other brands rest on a similar crystal-forming idea. None of them softens.
- Contact time
- How long water stays in a media tank. Carbon and arsenic media work better with more of it, so the flow through a tank is limited.
- Flow restrictor
- A small fitting that caps how fast water can pass through a tank, so the media gets the contact time it needs.
- Upflow
- Water entering a tank at the bottom and rising through the media. Charger runs its salt-free media this way only.
- Pre-oxidation
- A step ahead of an arsenic or iron system that changes what is in the water so the next stage can catch it: arsenic III into arsenic V, usually with chlorine, since air does little to arsenic III (EPA); or dissolved iron into particles, with air or chlorine.
- pH
- How acidic or alkaline water is, on a scale of 0 to 14: 7 is neutral, lower is acidic, higher is alkaline. Several makers’ limits on these sheets include a pH range.
- Coliform and E. coli
- Bacteria a lab tests for. Coliform bacteria are a sign that germs could be getting into the water; E. coli, one kind, comes from human or animal waste (CDC). A lab report lists them separately: “Total coliform: present” means coliform was found, even when E. coli is absent. Some reports write it as A (absent: none found, a pass) or P (present). A positive test means the source is found and fixed first.
- MPN
- Most probable number: a lab’s estimate of how many coliform bacteria are in 100 mL of water. On a well, coliform should be zero, so 0, “<1” or “absent” is a pass.
- Mixed-bed
- Charger’s name for a softener tank that holds more than one layer: on the Tigers, softening resin with a carbon layer in the same tank.
- Steady (service) flow and peak flow
- Steady flow is the rate a tank can treat water continuously and still do its job; a peak flow is a higher rate for a short time. The steady figures are the ones to plan on.
- In/out head
- A simple fitting on top of a tank with no timer or drain: water goes in and comes out, and the tank never backwashes.
- Anti-siphon device
- A fitting on a drain line that stops dirty water being pulled back into the equipment; codes call for it or an air gap.
- Tannins
- Natural matter from decaying plants that can tint water yellow or tea-colored. UV and arsenic media need water with little or none.
- Dissolved oxygen
- Oxygen carried in the water. Catalytic carbon needs enough of it to take out iron; Penn State says at least 4 ppm.
- Reject water (concentrate)
- The water an RO system sends to the drain, carrying what the membrane held back.
- Back pressure
- The push of a filling RO storage tank against the membrane. EPA says it makes a system less efficient than its rating: less water made, more to the drain.
- Leaching test (TCLP)
- EPA’s test of whether a used material would release contaminants in a landfill. Used-up arsenic media that passes it goes out as ordinary, non-hazardous waste.
- ppt (parts per trillion)
- A thousandth of a part per billion. PFAS limits are set in parts per trillion.
- UV dose (mJ/cm²)
- How much ultraviolet light the water receives. NSF/ANSI 55 Class A calls for 40.
- ADEQ
- The Arizona Department of Environmental Quality.
- Commissioning
- Starting up a new system and checking that it runs as its maker intends before it is handed over.
- Startup sample
- A water sample taken when a new system first runs, to check the result from the start.
- POE and POU
- Point of entry: treatment where the water comes into the house, so every tap gets it, as with the Jaguar’s AdEdge Medallion POE tanks. Point of use: treatment at one tap, as with an under-sink RO such as the Kitten.